Equotip 3 hardness tester manual
The Equotip is typically used for testing the hardness of metallic sur-faces. The user has a choice to select either Leeb rebound, the Portable Rockwell or UCI principle, see chapter “ Performing Measurements”. In combination with the Equotip Leeb Impact Device U the instrument is. · Equotip 3- Portable Metal Hardness Tester. • Large, easy to. Equotip uses a proven, dynamic testing principle. An impact body with a hard metal test tip is propelled by spring force against the surface of the test piece. The Equotip 3 Portable Hardness Tester is no longer available. The new Equotip Portable Hardness Tester has replaced the Equotip 3 Portable www.doorway.ru: Akizshura Kajit. As is standard practice for hardness measurements, the measuring location surface should be bright and smoothly ground. It does not have to be polished. Damage to the test piece surface after testing with EQUOTIP will be minimal. At least 2 to 3 test impacts should be made at each measuring location, and then in all cases the average should File Size: KB.
The Equotip is typically used for testing the hardness of metallic sur-faces. The user has a choice to select either Leeb rebound, the Portable Rockwell or UCI principle, see chapter “ Performing Measurements”. In combination with the Equotip Leeb Impact Device U the instrument is. EQUOTIP 3 PORTABLE HARDNESS TESTER. Equotip uses a proven, dynamic testing principle. An impact body with a hard metal test tip is propelled by spring force against the surface of the test piece. Surface deformation takes place when the impact body hits the test surface, which will result in loss of kinetic energy. This energy loss is detected bya comparison of velocities vi and vr when the impact body is at a precise distance from the surface for both the impact and rebound phase of the. The hardness tester EQUOTIP® 3 comprises an indicating device and an impact device. It is based on the rebound hardness testing method accord-ing to Leeb. It is for testing the hardness of all material surfaces over a large range of hardness quickly and independently. The unit displays in the hardness scales of: Leeb (HL) Vickers.
In addition to the Equostat 3 probe, all the impact devices of the Equotip metal hardness tester can be used to also conduct rebound hardness testing with the. EQUOTIP 2 Hardness measuring system Static low-load measurement based on the Rockwell principle 3 After relieving the supplementary test force. Heat Treatment Sales Services - Offering Equotip Portable Hardness Tester, Equotip Hardness Testing Machine, इक्कोटीप हार्डनेस.
0コメント